Water heater designed to operate indoors.
Casing of the unit is made of plastic. Fan motor with IP66 insulation class and thicker fins on heat exchanger with increased spacing make cleaning of the unit with water under pressure possible. Additionally, clamps which connect the confusor to the heat exchanger enable easy access to the inside of the unit. Such a construction makes the maintenance operations faster and helps in maintaining the unit clean and in optimal condition.
Protective coating, which covers the heat exchanger and used materials guarantee resistance to many corrosives.
LEO AGRO HP is designed for operation in agricultural buildings or pigg farms.
All of the FLOWAIR products have a complete control system. LEO AGRO units are available with simple ON/OFF control system, which has low investment cost.
Construction – heat exchanger with anti-corrosive coating. Fan motor with IP66 insulation class.
LEO AGRO HP | |
Max. air flow [m3/h] | 4600 |
Max. air flow range [m]* | 28 |
Power supply [V/Hz] | 230 / 50 |
Max. current consumption [A] | 2,5 |
Max. power consumption [W] | 360 |
IP / Insulation class | 66 / F |
Max. acoustic pressure level [dB(A)]** | 62 |
Max. heating water temperature [oC] | 95 |
Max. operating pressure [MPa] | 1,6 |
Hydraulic connection ["] | ¾” |
Max. operating temperature [oC] | 60 |
Weight [kg] | 27,3 |
Weight of unit filled with water [kg] | 31,0 |
* Range of horizontal, isothermal air stream at 0,5 m/s speed limit.
** Acoustic pressure level at a distance of 5 m from the unit, in the room of medium capabillity of sound absorption and 1500 m3 of cubic measure.
LEO AGRO HP | ||||||||||||||||||||
V = 4600m3/h | ||||||||||||||||||||
Tp1 | PT | Qw | ∆pw | Tp2 | PT | Qw | ∆pw | Tp2 | PT | Qw | ∆pw | Tp2 | PT | Qw | ∆pw | Tp2 | PT | Qw | ∆pw | Tp2 |
°C | kW | l/h | kPa | °C | kW | l/h | kPa | °C | kW | l/h | kPa | °C | kW | l/h | kPa | °C | kW | l/h | kPa | °C |
Tw1/Tw2 = 90/70°C | Tw1/Tw2 = 80/60°C | Tw1/Tw2 = 70/50°C | Tw1/Tw2 = 60/40°C | Tw1/Tw2 = 50/40°C | ||||||||||||||||
0 | 56,2 | 2480 | 20,0 | 34,0 | 48,6 | 2140 | 16,0 | 29,5 | 41 | 1800 | 12,0 | 25,0 | 33,4 | 1450 | 9,0 | 20,0 | 31,2 | 2710 | 26,0 | 19,0 |
5 | 52,0 | 2290 | 17,0 | 37,0 | 44,5 | 1950 | 13,0 | 32,5 | 36,9 | 1620 | 11,0 | 28,0 | 29,4 | 1280 | 7,0 | 23,0 | 27,2 | 2370 | 20,0 | 22,0 |
10 | 47,8 | 2110 | 15,0 | 40,0 | 40,4 | 1780 | 11,0 | 35,5 | 33 | 1440 | 9,0 | 30,5 | 25,5 | 1110 | 7,0 | 26,0 | 23,4 | 2030 | 15,0 | 24,5 |
15 | 43,8 | 1930 | 13,0 | 43,0 | 36,4 | 1600 | 10,0 | 38,0 | 29,1 | 1270 | 7,0 | 33,5 | 21,6 | 940 | 5,0 | 29,0 | 19,6 | 1710 | 12,0 | 27,5 |
20 | 39,8 | 1750 | 11,0 | 46,0 | 32,6 | 1430 | 8,0 | 41,0 | 25,3 | 1110 | 6,0 | 36,5 | 17,9 | 780 | 4,0 | 31,5 | 15,9 | 1380 | 8,0 | 30,5 |
V – air flow
PT – heating capacity
Tp1 – inlet air temperature
Tp2 – outlet air temperature
Tw1 – inlet water temperature
Tw2 – outlet water temperature
Qw – water flow rate in heat exchanger
Δpw – water pressure drop in heat exchanger
As LEO AGRO HP units can be installed using the installed installation supports for installation na parede. They allow you to build a unit for longe da parede to facilitate periodic maintenance or unit dismantling.
instalation brackets
ON/OFF regulation or stepless regulation via microclimate controller.
Use of outlet grille results in steady air distribution in the entire volume of the room. Additionally thanks to outlet grille the air stream is not directed directly to the animals.
TECHNICAL DATA:
Casing: galvanized sheet steel coated with corrosion protection primer and powder-painted
Colour: dark grey (RAL 7012)
Weight: 3,2kg
Dedicated for: LEO AGRO HP
Installation brackets for LEO AGRO SP - easy and quick installation of the unit, as well as optimum air flow around it.